Standing wave treatment applied to 3-level bistable system

S. S. Hassan, Surya P. Tewari, E. Abraham

Research output: Contribution to journalArticle

Abstract

A c-number treatment for the standing (plane) wave effects in a bistable system placed in a Fabry-Perot cavity is employed without "truncation of hierarchy" or "spatial average" procedure. The specific example of the 3-level Lambda-shape (two-photon) system is illustrated. © 1982.

Original languageEnglish
Pages (from-to)461-465
Number of pages5
JournalOptics Communications
Volume40
Issue number6
Publication statusPublished - 15 Feb 1982

Fingerprint

standing waves
hierarchies
plane waves
cavities
photons
approximation

Cite this

Hassan, S. S. ; Tewari, Surya P. ; Abraham, E. / Standing wave treatment applied to 3-level bistable system. In: Optics Communications. 1982 ; Vol. 40, No. 6. pp. 461-465.
@article{fcc7b6f511a341f8a331b1cf55163b81,
title = "Standing wave treatment applied to 3-level bistable system",
abstract = "A c-number treatment for the standing (plane) wave effects in a bistable system placed in a Fabry-Perot cavity is employed without {"}truncation of hierarchy{"} or {"}spatial average{"} procedure. The specific example of the 3-level Lambda-shape (two-photon) system is illustrated. {\circledC} 1982.",
author = "Hassan, {S. S.} and Tewari, {Surya P.} and E. Abraham",
year = "1982",
month = "2",
day = "15",
language = "English",
volume = "40",
pages = "461--465",
journal = "Optics Communications",
issn = "0030-4018",
publisher = "Elsevier",
number = "6",

}

Hassan, SS, Tewari, SP & Abraham, E 1982, 'Standing wave treatment applied to 3-level bistable system', Optics Communications, vol. 40, no. 6, pp. 461-465.

Standing wave treatment applied to 3-level bistable system. / Hassan, S. S.; Tewari, Surya P.; Abraham, E.

In: Optics Communications, Vol. 40, No. 6, 15.02.1982, p. 461-465.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Standing wave treatment applied to 3-level bistable system

AU - Hassan, S. S.

AU - Tewari, Surya P.

AU - Abraham, E.

PY - 1982/2/15

Y1 - 1982/2/15

N2 - A c-number treatment for the standing (plane) wave effects in a bistable system placed in a Fabry-Perot cavity is employed without "truncation of hierarchy" or "spatial average" procedure. The specific example of the 3-level Lambda-shape (two-photon) system is illustrated. © 1982.

AB - A c-number treatment for the standing (plane) wave effects in a bistable system placed in a Fabry-Perot cavity is employed without "truncation of hierarchy" or "spatial average" procedure. The specific example of the 3-level Lambda-shape (two-photon) system is illustrated. © 1982.

UR - http://www.scopus.com/inward/record.url?scp=0020090772&partnerID=8YFLogxK

M3 - Article

VL - 40

SP - 461

EP - 465

JO - Optics Communications

JF - Optics Communications

SN - 0030-4018

IS - 6

ER -