Removal of dissolved aromatics from water. Comparison of a high intensity contactor with a packed column

B. Waldie, W. K. Harris

Research output: Contribution to journalArticle

Abstract

An experimental comparison of the performances of a new high intensity contactor and a conventional packed column in stripping dissolved aromatics from water is described. The contactor gives significantly lower values of HOL. These, combined with the much higher liquid fluxes, give volumetric mass transfer coefficients, KLa, several hundred times higher than those for the packed column and substantially higher than those in the literature for bubble columns. Performance is particularly good on saline water due to suppression of bubble coalescence. That characteristic would be beneficial in the removal of aromatics from produced water in oil and gas production. The contactor utilizes enhanced acceleration fields achieved by water injection and so should be insensitive to the marine motion and tilt experienced on offshore floating production systems, as well as being compact. At constant water rate, KLa?Gn with n ranging from 0.50 to 0.92. Some preliminary results on the effects of liquid feed rate and initial bubble size are included, the latter confirming the importance of bubble size on performance. Pressure drop and consequent energy requirements are also considered.

Original languageEnglish
Pages (from-to)562-570
Number of pages9
JournalChemical Engineering Research and Design
Volume76
Issue numberA5
DOIs
Publication statusPublished - Jul 1998

Fingerprint

bubble
water
liquid
coalescence
pressure drop
gas production
tilt
production system
oil production
mass transfer
comparison
removal
energy
rate

Cite this

@article{bc5d744e65b848fb8c171aea197d9428,
title = "Removal of dissolved aromatics from water. Comparison of a high intensity contactor with a packed column",
abstract = "An experimental comparison of the performances of a new high intensity contactor and a conventional packed column in stripping dissolved aromatics from water is described. The contactor gives significantly lower values of HOL. These, combined with the much higher liquid fluxes, give volumetric mass transfer coefficients, KLa, several hundred times higher than those for the packed column and substantially higher than those in the literature for bubble columns. Performance is particularly good on saline water due to suppression of bubble coalescence. That characteristic would be beneficial in the removal of aromatics from produced water in oil and gas production. The contactor utilizes enhanced acceleration fields achieved by water injection and so should be insensitive to the marine motion and tilt experienced on offshore floating production systems, as well as being compact. At constant water rate, KLa?Gn with n ranging from 0.50 to 0.92. Some preliminary results on the effects of liquid feed rate and initial bubble size are included, the latter confirming the importance of bubble size on performance. Pressure drop and consequent energy requirements are also considered.",
author = "B. Waldie and Harris, {W. K.}",
year = "1998",
month = "7",
doi = "10.1205/026387698525243",
language = "English",
volume = "76",
pages = "562--570",
journal = "Chemical Engineering Research and Design",
issn = "0263-8762",
publisher = "Institution of Chemical Engineers",
number = "A5",

}

Removal of dissolved aromatics from water. Comparison of a high intensity contactor with a packed column. / Waldie, B.; Harris, W. K.

In: Chemical Engineering Research and Design, Vol. 76, No. A5, 07.1998, p. 562-570.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Removal of dissolved aromatics from water. Comparison of a high intensity contactor with a packed column

AU - Waldie, B.

AU - Harris, W. K.

PY - 1998/7

Y1 - 1998/7

N2 - An experimental comparison of the performances of a new high intensity contactor and a conventional packed column in stripping dissolved aromatics from water is described. The contactor gives significantly lower values of HOL. These, combined with the much higher liquid fluxes, give volumetric mass transfer coefficients, KLa, several hundred times higher than those for the packed column and substantially higher than those in the literature for bubble columns. Performance is particularly good on saline water due to suppression of bubble coalescence. That characteristic would be beneficial in the removal of aromatics from produced water in oil and gas production. The contactor utilizes enhanced acceleration fields achieved by water injection and so should be insensitive to the marine motion and tilt experienced on offshore floating production systems, as well as being compact. At constant water rate, KLa?Gn with n ranging from 0.50 to 0.92. Some preliminary results on the effects of liquid feed rate and initial bubble size are included, the latter confirming the importance of bubble size on performance. Pressure drop and consequent energy requirements are also considered.

AB - An experimental comparison of the performances of a new high intensity contactor and a conventional packed column in stripping dissolved aromatics from water is described. The contactor gives significantly lower values of HOL. These, combined with the much higher liquid fluxes, give volumetric mass transfer coefficients, KLa, several hundred times higher than those for the packed column and substantially higher than those in the literature for bubble columns. Performance is particularly good on saline water due to suppression of bubble coalescence. That characteristic would be beneficial in the removal of aromatics from produced water in oil and gas production. The contactor utilizes enhanced acceleration fields achieved by water injection and so should be insensitive to the marine motion and tilt experienced on offshore floating production systems, as well as being compact. At constant water rate, KLa?Gn with n ranging from 0.50 to 0.92. Some preliminary results on the effects of liquid feed rate and initial bubble size are included, the latter confirming the importance of bubble size on performance. Pressure drop and consequent energy requirements are also considered.

UR - http://www.scopus.com/inward/record.url?scp=0032125082&partnerID=8YFLogxK

U2 - 10.1205/026387698525243

DO - 10.1205/026387698525243

M3 - Article

VL - 76

SP - 562

EP - 570

JO - Chemical Engineering Research and Design

JF - Chemical Engineering Research and Design

SN - 0263-8762

IS - A5

ER -