Abstract
A simple washing model has been proposed to identify optimum cycle time for a double stage pulp washer. The change in conductivity of water in washing has been expressed in the form of a first-order rate equation. The test results under actual operating conditions in a plant indicates 20% reduction in fresh water consumption.
Original language | English |
---|---|
Pages | 65-68 |
Number of pages | 4 |
Volume | 33 |
No. | 6 |
Specialist publication | Chemical Engineering World |
Publication status | Published - Jun 1998 |
ASJC Scopus subject areas
- General Chemistry
- General Chemical Engineering
- Industrial and Manufacturing Engineering