T1 - Nonlinear micro finite element models based on digital volume correlation measurements predict early microdamage in newly formed bone
AU - Peña Fernández, Marta
AU - Sasso, Sebastian J.
AU - Mcphee, Samuel
AU - Black, Cameron
AU - Kanczler, Janos
AU - Tozzi, Gianluca
AU - Wolfram, Uwe
N1 - Funding Information:
Marta Peña Fernández and Uwe Wolfram were supported by the Leverhulme Trust ( RPG-2020-215 ). The authors would like to acknowledge Enrico Dall’Ara for providing the calibration phantom. We further acknowledge Richard Oreffo, Jon Dawson, and David Gibbs for providing the bone specimens. Funding for the original ovine studies to Professor Oreffo from the Biotechnology and Biological Sciences Research Council ( BBSRC LO21071/ , BB/G010579/1 , and BB/L00609X/1 ) and UK Regenerative Medicine Platform Hub Acellular Approaches for Therapeutic Delivery ( MR/K026682/1 ) is gratefully acknowledged.
Publisher Copyright:
© 2022 The Authors
PY - 2022/8
Y1 - 2022/8
N2 - Bone regeneration in critical-sized defects is a clinical challenge, with biomaterials under constant development aiming at enhancing the natural bone healing process. The delivery of bone morphogenetic proteins (BMPs) in appropriate carriers represents a promising strategy for bone defect treatment but optimisation of the spatial-temporal release is still needed for the regeneration of bone with biological, structural, and mechanical properties comparable to the native tissue. Nonlinear micro finite element (μFE) models can address some of these challenges by providing a tool able to predict the biomechanical strength and microdamage onset in newly formed bone when subjected to physiological or supraphysiological loads. Yet, these models need to be validated against experimental data. In this study, experimental local displacements in newly formed bone induced by osteoinductive biomaterials subjected to in situ X-ray computed tomography compression in the apparent elastic regime and measured using digital volume correlation (DVC) were used to validate μFE models. Displacement predictions from homogeneous linear μFE models were highly correlated to DVC-measured local displacements, while tissue heterogeneity capturing mineralisation differences showed negligible effects. Nonlinear μFE models improved the correlation and showed that tissue microdamage occurs at low apparent strains. Microdamage seemed to occur next to large cavities or in biomaterial-induced thin trabeculae, independent of the mineralisation. While localisation of plastic strain accumulation was similar, the amount of damage accumulated in these locations was slightly higher when including material heterogeneity. These results demonstrate the ability of the nonlinear μFE model to capture local microdamage in newly formed bone tissue and can be exploited to improve the current understanding of healing bone and mechanical competence. This will ultimately aid the development of BMPs delivery systems for bone defect treatment able to regenerate bone with optimal biological, mechanical, and structural properties.
AB - Bone regeneration in critical-sized defects is a clinical challenge, with biomaterials under constant development aiming at enhancing the natural bone healing process. The delivery of bone morphogenetic proteins (BMPs) in appropriate carriers represents a promising strategy for bone defect treatment but optimisation of the spatial-temporal release is still needed for the regeneration of bone with biological, structural, and mechanical properties comparable to the native tissue. Nonlinear micro finite element (μFE) models can address some of these challenges by providing a tool able to predict the biomechanical strength and microdamage onset in newly formed bone when subjected to physiological or supraphysiological loads. Yet, these models need to be validated against experimental data. In this study, experimental local displacements in newly formed bone induced by osteoinductive biomaterials subjected to in situ X-ray computed tomography compression in the apparent elastic regime and measured using digital volume correlation (DVC) were used to validate μFE models. Displacement predictions from homogeneous linear μFE models were highly correlated to DVC-measured local displacements, while tissue heterogeneity capturing mineralisation differences showed negligible effects. Nonlinear μFE models improved the correlation and showed that tissue microdamage occurs at low apparent strains. Microdamage seemed to occur next to large cavities or in biomaterial-induced thin trabeculae, independent of the mineralisation. While localisation of plastic strain accumulation was similar, the amount of damage accumulated in these locations was slightly higher when including material heterogeneity. These results demonstrate the ability of the nonlinear μFE model to capture local microdamage in newly formed bone tissue and can be exploited to improve the current understanding of healing bone and mechanical competence. This will ultimately aid the development of BMPs delivery systems for bone defect treatment able to regenerate bone with optimal biological, mechanical, and structural properties.
KW - Biomaterials
KW - Bone regeneration
KW - Digital volume correlation
KW - Micro finite element models
KW - Microdamage
UR - http://www.scopus.com/inward/record.url?scp=85131444355&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2022.105303
DO - 10.1016/j.jmbbm.2022.105303
M3 - Article
C2 - 35671669
SN - 1751-6161
VL - 132
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
M1 - 105303
ER -