Abstract
We describe improvements to a time-of-flight sensor utilising the time-correlated single-photon counting technique employing a commercially-available silicon-based photon-counting module. By making modifications to the single-photon detection circuitry and the data analysis techniques, we experimentally demonstrate improved resolution between multiple scattering surfaces with a minimum resolvable separation of 1.7 cm at ranges in excess of several hundred metres. © 2007 Optical Society of America.
Original language | English |
---|---|
Pages (from-to) | 423-429 |
Number of pages | 7 |
Journal | Optics Express |
Volume | 15 |
Issue number | 2 |
Publication status | Published - 22 Jan 2007 |