Comment on 'particle velocity profiles and solid flow patterns in spouted beds', Y.-L. He, S.-Z. Qin, C. J. Lim and J. R. Grace, Can. J. Chem. Eng. 72, 561-568 (1994)

B. Waldie

Research output: Contribution to journalArticlepeer-review

Abstract

In a recent paper, He et al. (1994) described the use of fiber optic probe system to measure profiles of vertical particle velocities in the spout and fountain of half-section and full-section spouted beds. They state that the question of whether the flat plate in a half-section column effects particle velocity had not been investigated previously. This letter reverses this statement by He and his co-workers and attests that the subject, in fact, was investigated and quantitative data were obtained by Boulos and Waldie (1985, 1986) who used laser doppler anemometry.

Original languageEnglish
Pages (from-to)176-
JournalCanadian Journal of Chemical Engineering
Volume74
Issue number1
Publication statusPublished - Feb 1996

Fingerprint

Dive into the research topics of 'Comment on 'particle velocity profiles and solid flow patterns in spouted beds', Y.-L. He, S.-Z. Qin, C. J. Lim and J. R. Grace, Can. J. Chem. Eng. 72, 561-568 (1994)'. Together they form a unique fingerprint.