TY - JOUR
T1 - Combining perforated ceiling and attic ventilation for night cooling in a single-zone building: CFD analysis
AU - Sudirman, Mutmainnah
AU - van Hooff, Twan
AU - Gillmeier, Stefanie
AU - Blocken, Bert
PY - 2025/12/5
Y1 - 2025/12/5
N2 - The ventilative cooling potential of a perforated ceiling in combination with attic ventilation during the night in naturally ventilated residential buildings in tropical climate is investigated. 3D steady Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) simulations were carried out with the RNG k-ε turbulence model under non-isothermal conditions for two different single zone realistic building models, C1 (building without perforated ceiling and attic ventilation) and C2 (with perforated ceiling (40% porosity) and attic ventilation). The simulations were conducted for nighttime conditions in Indonesia (Makassar), as obtained from measured weather data, to represent real-life conditions as much as possible. The CFD simulations were performed for the wind direction perpendicular to the building facade with the window openings. The heat removal effectiveness (HRE) and air changes per hour (ACH) were assessed for both building configurations. The results show that building C2 facilitates a faster removal of heat from the occupied zone compared to building C1. This leads to a reduction of indoor air temperature that is lower by 0.8 °C for case C2 compared to case C1. Moreover, C2 displays higher values for both HRE (1.25 vs. 1.00) and ACH (34.1 h-1 vs. 27.9 h-1 ).
AB - The ventilative cooling potential of a perforated ceiling in combination with attic ventilation during the night in naturally ventilated residential buildings in tropical climate is investigated. 3D steady Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) simulations were carried out with the RNG k-ε turbulence model under non-isothermal conditions for two different single zone realistic building models, C1 (building without perforated ceiling and attic ventilation) and C2 (with perforated ceiling (40% porosity) and attic ventilation). The simulations were conducted for nighttime conditions in Indonesia (Makassar), as obtained from measured weather data, to represent real-life conditions as much as possible. The CFD simulations were performed for the wind direction perpendicular to the building facade with the window openings. The heat removal effectiveness (HRE) and air changes per hour (ACH) were assessed for both building configurations. The results show that building C2 facilitates a faster removal of heat from the occupied zone compared to building C1. This leads to a reduction of indoor air temperature that is lower by 0.8 °C for case C2 compared to case C1. Moreover, C2 displays higher values for both HRE (1.25 vs. 1.00) and ACH (34.1 h-1 vs. 27.9 h-1 ).
U2 - 10.1051/e3sconf/202567207034
DO - 10.1051/e3sconf/202567207034
M3 - Conference article
SN - 2555-0403
VL - 672
JO - E3S Web of Conferences
JF - E3S Web of Conferences
M1 - 07034
T2 - 17th ROOMVENT Conference 2024
Y2 - 22 April 2024 through 25 April 2024
ER -