TY - JOUR
T1 - Capacitive Sensing for Monitoring of Microfluidic Protocols Using Nanoliter Dispensing and Acoustic Mixing
AU - Zhang, Yaqi
AU - Sesen, Muhsincan
AU - de Marco, Alex
AU - Neild, Adrian
PY - 2020/8/4
Y1 - 2020/8/4
N2 - The development of protocols for bio/chemical reaction requires alternate dispensing and mixing steps. While most microfluidic systems use the opening of additional parts of the channel to allow the ingress of fixed volumes of fluid, this requires knowledge of the protocol before the design of the chip. Our approach of using a microfluidic valve to regulate the flow into an initially empty cavity allows for on-chip protocol development and refinement. Mixing is provided by way of surface acoustic wave excitation; this high-frequency vibration causes steady-state streaming flows. We show that capacitive sensing can be used to measure fluid levels, even if multiple fluid types are used, such that nanoliter dispensing accuracy is achieved. Also, the capacitive readout can be used to establish mixing quality and to monitor temperature fluctuations. These capabilities allow for protocols to be conducted without optical assessment and thus will allow for multiplexing, such that reactions could be conducted, simultaneously, in multiple chambers across a chip.
AB - The development of protocols for bio/chemical reaction requires alternate dispensing and mixing steps. While most microfluidic systems use the opening of additional parts of the channel to allow the ingress of fixed volumes of fluid, this requires knowledge of the protocol before the design of the chip. Our approach of using a microfluidic valve to regulate the flow into an initially empty cavity allows for on-chip protocol development and refinement. Mixing is provided by way of surface acoustic wave excitation; this high-frequency vibration causes steady-state streaming flows. We show that capacitive sensing can be used to measure fluid levels, even if multiple fluid types are used, such that nanoliter dispensing accuracy is achieved. Also, the capacitive readout can be used to establish mixing quality and to monitor temperature fluctuations. These capabilities allow for protocols to be conducted without optical assessment and thus will allow for multiplexing, such that reactions could be conducted, simultaneously, in multiple chambers across a chip.
UR - http://www.scopus.com/inward/record.url?scp=85090866816&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.0c01906
DO - 10.1021/acs.analchem.0c01906
M3 - Article
C2 - 32627542
AN - SCOPUS:85090866816
SN - 0003-2700
VL - 92
SP - 10725
EP - 10732
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 15