Abstract
A simple analytical model of the Trombe wall is considered in which all the various parameters affecting the wall performance can be analyzed. Several design criteria for optimizing the wall performance are considered, and comparisons with previous methods are given. © 1985.
Original language | English |
---|---|
Pages (from-to) | 69-72 |
Number of pages | 4 |
Journal | Solar Energy |
Volume | 34 |
Issue number | 1 |
Publication status | Published - 1985 |