A new respiratory gating device to improve 4D PET/CT

David Didierlaurent*, Sophie Ribes, Olivier Caselles, Cyril Jaudet, Jean Marc Cazalet, Hadj Batatia, Frédéric Courbon

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

14 Citations (Scopus)

Abstract

Purpose: Respiratory motion creates artifacts in positon emission tomography with computed tomography (PET/CT) images especially for lung tumors, and can alter diagnosis. To account for motion effects, respiratory gating techniques have been developed. However, the lack of measures strongly correlated with tumor motion limits their accuracy. The authors developed a real-time pneumotachograph device (SPI) allowing to sort PET and CT images depending on lung volumes. Methods: The performance of this innovative respiratory tracking system was characterized and compared to a standard system. Our experimental setup consisted in a movable platform and a thorax phantom with six fillable spheres simulating lung tumors. The accuracy of SPI to detect inhalation peaks was also determined on volunteers. A comparison with the real-time position management (RPM) device, that relies on abdominal height measurement, was then investigated. Results: Experiments showed a high accuracy of the measured signal compared to the input signal (R = 0.88 to 0.99), and of the detection of the inhalation peaks (error of 0.1 +/- 5.8 ms) necessary for prospective binning mode. Activity recovery coefficient was improved (until +39%) and the smearing effect was reduced (until 2.74 times lower) with SPI compared to ungated PET/CT acquisition. The spatial distribution of activity in spheres was similar for 4D PET gated with SPI and RPM. Significant improvement of the binning stability and matching between PET and CT were highlighted for irregular breathing patterns with SPI. Conclusions: SPI is an innovative device that provides better binning performance than the current gating device on phantom experiments. Future works will focus on patients where the authors expect a significant improvement of specificity and sensitivity of PET/CT examinations.

Original languageEnglish
Article number032501
JournalMedical Physics
Volume40
Issue number3
DOIs
Publication statusPublished - Mar 2013

Keywords

  • 4D PET/CT
  • gating device
  • pneumotachograph

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'A new respiratory gating device to improve 4D PET/CT'. Together they form a unique fingerprint.

Cite this