Abstract
This paper presents a proposed photovoltaic array (PVA) model designed to decrease the simulation time when more than one PVA systems are connected in a microgrid. The proposed model is compared with a common PVA model, both implemented on MatLab-Simulink environment, using basic circuit equations of the photovoltaic (PV) solar cells. The two models are tested using a dc-dc boost converter coupled via an inverter per PVA system with a microgrid. The simulation of the proposed model is significantly faster.
| Original language | English |
|---|---|
| Title of host publication | Applied Simulation and Modelling 2011 |
| Publisher | ACTA Press |
| Number of pages | 6 |
| Volume | 715 |
| ISBN (Electronic) | 978-0-88986-884-7 |
| ISBN (Print) | 978-0-88986-893-9 |
| DOIs | |
| Publication status | Published - 2011 |
| Event | IASTED International Conference: Applied Simulation and Modelling - Crete, Greece Duration: 22 Jun 2011 → 24 Jan 2013 |
Conference
| Conference | IASTED International Conference: Applied Simulation and Modelling |
|---|---|
| Abbreviated title | ASM 2011 |
| Country/Territory | Greece |
| City | Crete |
| Period | 22/06/11 → 24/01/13 |